TD-4100 Oil in Water Monitor
An Overview
The Turner Designs TD-4100 reliably detects BTEX, gasoline, diesel, jet fuel and oil in water. The TD-4100 is a nonfouling continuous, on-line monitor that provides hydrocarbon and oil in water monitoring down to low ppb. The TD-4100 is installed for applications that require monitoring of treated and untreated wastewater streams ranging from industrial wastewater, groundwater, process water, produced, potable water intakes, and storm water run-off.
Why Continuous On-Line Monitoring?
Continuous on-line monitoring provides the most responsive feedback loop for measuring hydrocarbons in water. Continuous monitoring is reliable, effective, and recognized for its ability to improve process management for treating, discharging and detecting hydrocarbons in water. Compared to laboratory grab sample analysis, on-line monitoring provides cost effective, continuous, remote, operator unattended measurement of aromatic hydrocarbons in water.
Features of the TD-4100
The Unique Flowcell. The TD-4100 does not have a glass flow cell. Hydrocarbons are detected in a stream of water which falls through an open chamber; the stream does not contact, dirty or foul the optical windows used for oil in water monitoring. A proprietary Air Curtain system keeps optical Windows fog-free in humid environments or hot water applications.
Low Maintenance. There are no tubes, pumps or valves to replace. The systems one moving part has a life expectancy of greater than 5 years. Routine maintenance involves changing a lamp twice a year and an air filter periodically.
Direct, Continuous Monitoring. The TD-4100 monitors a flowing water stream continuously. No chemicals, no pre-treatment and no manual manipulation of the sample are required to monitor aromatic hydrocarbons.
Accurate. The TD-4100 directly measures aromatic hydrocarbons in water with accuracies that consistently correlate to regulated laboratory methods.
Sensitive. BTEX, gasoline, diesel, jet fuel, crude oil, aromatic solvents and refined petroleum products containing aromatics are detected by the TD-4100 from low ppb (ug/L) to high ppm (mg/L). For example, the TD-4100 can detect 5 ppb of gasoline or diesel fuel in water free of interfering compounds.
Selective. The TD-4100 continuously measures the fluorescence of aromatic hydrocarbon compounds in water. Fluorescence occurs when a molecule absorbs light energy of one specific wavelength and emits light energy of a longer wavelength. Fluorescent compounds each have a unique signature, and these compounds can be displayed as an actual concentration.
Effective Monitoring in Dirty Water. Monitoring fluorescence makes the TD-4100 resistant to interferences by turbid or dirty water which impact on-line UV or IR light scatter instruments. Most substances absorb light, but very few fluoresce; if a substance does not fluoresce at specific wavelengths for the monitored aromatic hydrocarbon, it will not interfere.
Operator Friendly. The TD-4100 is designed for easy operation. Simple on-board software controls alarms, 4-20 mA output, diagnostics and calibration.
Applications exist in the fields of...
- Upset Monitoring
- Discharge Monitoring
- Continuous Monitoring
- Process Control
- Carbon Break-thru
- Oil/Water Separators
- Treatment Verification
- Hydrocarbon Leak Detection
- Pollution Prevention
- Regulatory Compliance
TD-4100 Specifications
| Dimensions: |
44.0" x 43.1" x 10.8" (111.8 cm x 109.4 cm x 27.5 cm) |
| Weight: |
64 lbs (29 kg) |
| Power Requirements: |
110 - 240 VAC, 50/60 Hz, 2A |
| Plumbing Requirements: |
Feed: 0.5 - 2 gpm (2 - 8L/min), 2" (5.01 cm) unrestricted drain |
| Air Supply: |
Dry Air: 10 - 100 psi (68.9 - 689 kPa), 15 SCFH (246 cm3H) |
| Operating Temperature: |
32 - 120o F (0 - 49o C). Contact Turner Designs for configurations in extreme environmental conditions. |
| Operational Principle: |
Fluorescence |
| Detection Range: |
1 ppb - > 1000 ppm* |
| Calibration Stability: |
10% or better over 90 days |
| Response Time: |
< 10 sec |
| Sample Temperature: |
190o F (95o C) (max) |
| Calibration: |
Multi-point calibration |
| Alarms: |
Three alarm trigger points (baseline, early warning, and high alarm). Critical components linked to alarms: Local Alarm: Local beep tone; LCD alarm message |
| Outputs: |
Signal: 4 - 20 mA, isolated. External Alarm/Device Control: 2 user-settable, independently-fused, solid-state relays (optional AC relay or optional DC relay); relays configurable as Normally Open or Normally Closed; user settable set points and delays |
| Diagnostics: |
Self diagnostics: Internal failure mode linked to relays and LCD display |
| Security: |
Password protected for Master and User ID; padlockable cabinet |
| Electronics Cabinet: |
NEMA 4X |
| Maintenance: |
Lamp (twice yearly); routine cleaning of plumbing |
| Air Purge (optional): |
Class I Division I; Class I Division II (explosion-proofing) |
| Data Logger (optional): |
Digital data storage |
©2007 Turner Designs Hydrocarbon Instruments
2023 North Gateway, Suite 101
Fresno, CA 93727
(559) 253-1414
(559) 253-1090 - Fax
Gulf Coast Office
2200 N. Loop West #126
Houston, TX 77018
(713) 263-9099
(713) 263-9228 - Fax
|
|
What's New
Turner Designs Hydrocarbon Instruments will be attending Hydrovision 2008
to showcase Oil in Water Monitors for the HydroElectric Industry, Come see our booth at the Sacramento Convention Center, Booth 534.
July 14 - 18, 2008
OTC -2008 Recap
read more
Hydroelectric Sump Monitoring with the new TD-1000C Oil in Water Monitor read more
February 14, 2008
Turner Designs Hydrocarbon Instruments, Inc. of Fresno, CA USA announces Roger McEvoy has joined their staff as the new Sales Engineer.
read more >
As seen in
Process Heating
Oil Leak Detection in Heating and Cooling Systems
read more >
As seen in
Process Cooling
October 2007
Heat exchanger monitoring and protection using UV fluorescence technology
read more >
December 11, 2007
Analysis For Hydrocarbons in Glycol.
Refineries and Gas Processing Plants use Glycol to dehydrate oil and gas, reducing the amount of water to less than 0.5%. Once the glycol has dehydrated the hydrocarbon the glycol is “rich” with water and hydrocarbon.
read more >
November 14, 2007
Turner Designs Hydrocarbon Instruments, Inc. announces the success of their 2007 Dealer Training in Fresno CA. read more >.
November 14, 2007
Turner designs Hydrocarbon Instruments, Inc. of Fresno, CA USA announces Shawana Lillard will join their staff as Marketing Assistant to Gary Bartman, President. read more >
The TD-1000C Oil in water monitor for oil leak detection in steam condensate and process cooling water is now available from Turner Designs Hydrocarbon Instruments, Inc., Fresno California.
The low cost and low maintenance TD-1000C is a fluorescence technology based instrument with the lowest detection limits on the market. It can detect fuel oil in steam condensate at below 50ppb (parts per billion).
read more >
Use of TD-500D Oil in Water Analyzer by US Coast Guard's Enforcement Unit
Oil in water monitoring experts Turner Designs Hydrocarbon Instruments announce the use of their TD 500D portable oil in water analyzer by US Coast Guard’s enforcement unit to check the oil content in water from ship’s Oily Water Separators & Overboard discharges.
read more >
Houston Office Opening
Turner Designs Hydrocarbon Instruments, Inc. is pleased to announce the opening of a Sales and Service Office in Houston.
read more >
Oil Leak Detection in Heat Exchangers for Heating and Cooling Systems
Turner Designs Hydrocarbon Instruments introduces the new ‘C’ series of continuous on-line oil in water monitoring instruments.
read more >
Major oil in water monitor supply contract won by Turner Designs Hydrocarbon Instruments, Inc.
Turner Designs Hydrocarbon Instruments of Fresno, CA USA has won one of the largest oil in water monitor supply contracts in the history of the offshore oil and FPSO business.
read more >
Portable Oil in Water Analyzer New Dual-Channel TD-500D
Turner Designs Hydrocarbon Instruments, Inc. announces a major improvement to their very popular TD-500 handheld oil in water analyzer.
read more >
TD-4100 Oil in Water Monitor bilge alarm receives US Coast Guard certification for IMO Resolution MEPC.107(49)!
Turner Designs Hydrocarbon Instruments, Inc. of Fresno, CA, USA announces that the USCG has completed the certification of the TD-4100 for bilge water monitoring per International Maritime Organization requirements MEPC.107(49).
read more >
Crude Oil Spill on the Ohio River Monitored by the TD-500 Oil in Water Meter
Turner Designs Hydrocarbon Instruments, Inc. is helping the Ohio River Valley Water Sanitation Commission (ORSANCO) in monitoring the 63,000 gallon crude oil spill on the Ohio River.
read more >
Oil Spill / Oil in Water Analyzer, hand held, accurate and repeatable results in less than 4 minutes. TD-500 Oil in Water Analyzer is available from stock for immediate delivery from Turner Designs Hydrocarbon Instruments, California, USA. Detect crude oil spills such as that on the Delaware River USA in minutes using the same proven field method used on the world’s offshore oil production platforms. Sensitivity to crude oil down to less than 1 ppm in water.
Turner Designs Hydrocarbon Instruments supplies single sample analyzers and continuous on-line oil in water analyzers to all industries from drinking water to power plants, to heavy industry and oil production facilities worldwide. Contact Turner Designs Hydrocarbon Instruments at sales@oilinwatermonitors.com or 1-559 253-1414.

New Hand Held Oil in Water Meter for Produced Water and Crude Oil in Water
Turner Designs Hydrocarbon Instruments (USA) announces the next generation rugged and reliable oil field oil in water monitors for crude oil and produced water applications. The industry leader who brought you the TD-360 FastHEX and the TD-4100 XD continuous on-line oil in water monitors has just released the TD-500 TM hand held / bench top oil in water meter for crude oil. The new UV Fluorescence meter measures oil in Produced Water, Desalter Tail-Water, Crude Storage Tank Water, and in any application where crude oil may be in contact with water. It is viable for all crude oil and most gas production condensates.
It uses the same easy-to-use FastHEX procedure used on the famous TD-360 with the same high accuracy and repeatability but the new TD-500 meter is half the price of the nearest competition. The analysis method is compatible with all popular solvents including hexane, Vertrel, AK-225, Freon, xylene, and others.
The TD-500 is powered by 4 AAA batteries, weighs less than 1 pound and produces oil in water measurements in less than 4 minutes. It requires no special training and measurements correlate to EPA standard oil and grease laboratory methods. It is completely sealed meeting IP 67 Standard. It is water-proof, dust-proof and corrosion-proof and carries the CE mark.
TD500 Fact Sheet

|
|