TD-3100 Laboratory Fluorometer

An Overview

The TD-3100 is a low cost benchtop instrument that was developed to provide an alternative to industry standard oil and grease methods. Measure samples directly (non-extraction) or with solvent (i.e. hexane) extraction methods.

TD-3100 Features

  • Simple set-up and calibration
  • Low cost per sample analysis
  • Less than 10 seconds per sample
  • Calibrated methods for quantitative analysis
  • Un-calibrated method for relative measurements
  • Results correlate to standard methods
  • Quick-change optics for multiple applications
  • Detection limits range from ppb to ppm depending on application
  • Solid Reference Standards available for quick performance checks
  • Sample compartment accommodates 25 x 150 mm round, 13 x 100 mm round, or 10 x 10 mm square cuvettes

Applications include:

  • Heat Exchanger Leak Detection
  • Produced Water
  • Industrial Wastewater
  • Ground Water
  • Storm Water
  • Bilge Water
  • Soil Extract Analysis

Target Hydrocarbons

  • Crude Oil
  • BTEX
  • Phenol
  • Styrene
  • Gasoline
  • Diesel
  • Jet Fuel
  • Fuel Oils
  • Kerosene
  • Heat Transfer Fluids
  • Transformer Oils
  • Lube Oils
  • Hydraulic Oils

Product Specifications

Detection Limits: Ranges from ppb to ppm depending on application.
Power: External power supply, 100-240 VAC, Max. 30 watts.
Dimensions: 23.5 cm W x 28 cm D x 21 cm H, (9.25" W x 11" D x 8.25" H).
Weight: 5.9 Kg (13 lbs).
Operating Temperature: 60 - 95°F; 15 - 36°C.
Display: 16 x 2 character LCD; (3.86" x .86"; 9.8 cm x 2.18 cm).
Keypad: 4 x 5 keys (3" x 2.7"; 7.62 cm x 6.86 cm).
Data Output: 100% ASCII format through a 9-pin RS-232 serial cable at 9600 baud.
Sample Adapters: Sample chamber with the 25 mm adapter accommodates 25 x 150 mm test tubes. Also includes adapter for 13 x 100 mm test tubes. Optional adapter for 10 x 10 x 45 mm square cuvettes. Optional range extending adapter with variable apertures for 10 x 10 x 45 mm square cuvettes.
Filter Cylinder: Accommodates eight, 1-inch round filters, (four excitation and four emission).
Software: Menu-driven microprocessor-controlled.
Detector: Factory-installed photomultiplier tube. Standard: 300 - 650 nm. Optional Red Sensitive: 185 - 870 nm.
Lamp: Quartz Halogen Lamp (20 watts; Lamp Life = 2000 hours) or Low Pressure Mercury Vapor Lamp (4 watts; Lamp Life = 8000 hours).
Printer: Optional EpsonTM printer (27 cm W x 36 cm D x 13 cm H; 10.8" W x 14.4" D x 5.2" H) or Serial Printer (19.75 cm W x 20 cm D x 9.5 cm H; 7.9" W x 8.0" D x 3.8" H).
Material: UL-approved polyurethane. Sheet metal back and base.
Readout: Direct Concentration or Raw Fluorescence.
Calibration: Multi-point Calibration for Direct Concentration Measurement or Single Point Raw Fluorescence Calibration.
Blank: Reads and subtracts Blank.
Discrete Sample Averaging: Sample readings can be averaged to improve accuracy (7-second delay; 12-second signal averaging; 5-second display readout).
Warranty: One-year warranty.
Approvals: CE, TUV, UL, and C-UL

 


©2007 Turner Designs Hydrocarbon Instruments
2023 North Gateway, Suite 101
Fresno, CA 93727

(559) 253-1414
(559) 253-1090
- Fax

Gulf Coast Office
2200 N. Loop West #126
Houston, TX 77018

(713) 263-9099
(713) 263-9228 - Fax

Technical Data Sheet

TD-3100 Benchtop Instrument


What's New

Turner Designs Hydrocarbon Instruments will be attending Hydrovision 2008
to showcase Oil in Water Monitors for the HydroElectric Industry, Come see our booth at the Sacramento Convention Center, Booth 534.
July 14 - 18, 2008


OTC -2008 Recap
read more

Hydroelectric Sump Monitoring with the new TD-1000C Oil in Water Monitor read more


February 14, 2008
Turner Designs Hydrocarbon Instruments, Inc. of Fresno, CA USA announces Roger McEvoy has joined their staff as the new Sales Engineer.
read more >

As seen in
Process Heating
Oil Leak Detection in Heating and Cooling Systems
read more >

As seen in
Process Cooling
October 2007
Heat exchanger monitoring and protection using UV fluorescence technology
read more >

December 11, 2007
Analysis For Hydrocarbons in Glycol.
Refineries and Gas Processing Plants use Glycol to dehydrate oil and gas, reducing the amount of water to less than 0.5%.  Once the glycol has dehydrated the hydrocarbon the glycol is “rich” with water and hydrocarbon.
read more >

November 14, 2007
Turner Designs Hydrocarbon Instruments, Inc. announces the success of their 2007 Dealer Training in Fresno CA. read more >.

November 14, 2007
Turner designs Hydrocarbon Instruments, Inc. of Fresno, CA USA announces Shawana Lillard will join their staff as Marketing Assistant to Gary Bartman, President. read more >


The TD-1000C Oil in water monitor for oil leak detection in steam condensate and process cooling water is now available from Turner Designs Hydrocarbon Instruments, Inc., Fresno California.

The low cost and low maintenance TD-1000C is a fluorescence technology based instrument with the lowest detection limits on the market. It can detect fuel oil in steam condensate at below 50ppb (parts per billion).
read more >


Use of TD-500D Oil in Water Analyzer by US Coast Guard's Enforcement Unit

Oil in water monitoring experts Turner Designs Hydrocarbon Instruments announce the use of their TD 500D portable oil in water analyzer by US Coast Guard’s enforcement unit to check the oil content in water from ship’s Oily Water Separators & Overboard discharges. 
read more >


Houston Office Opening

Turner Designs Hydrocarbon Instruments, Inc. is pleased to announce the opening of a Sales and Service Office in Houston.
read more >


Oil Leak Detection in Heat Exchangers for Heating and Cooling Systems

Turner Designs Hydrocarbon Instruments introduces the new ‘C’ series of continuous on-line oil in water monitoring instruments.
read more >

Major oil in water monitor supply contract won by Turner Designs Hydrocarbon Instruments, Inc.

Turner Designs Hydrocarbon Instruments of Fresno, CA USA has won one of the largest oil in water monitor supply contracts in the history of the offshore oil and FPSO business.
read more >

Portable Oil in Water Analyzer New Dual-Channel TD-500D

Turner Designs Hydrocarbon Instruments, Inc. announces a major improvement to their very popular TD-500 handheld oil in water analyzer. 
read more >

TD-4100 Oil in Water Monitor bilge alarm receives US Coast Guard certification for IMO Resolution MEPC.107(49)!

Turner Designs Hydrocarbon Instruments, Inc. of Fresno, CA, USA announces that the USCG has completed the certification of the TD-4100 for bilge water monitoring per International Maritime Organization requirements MEPC.107(49).
read more >

Crude Oil Spill on the Ohio River Monitored by the TD-500 Oil in Water Meter

Turner Designs Hydrocarbon Instruments, Inc. is helping the Ohio River Valley Water Sanitation Commission (ORSANCO) in monitoring the 63,000 gallon crude oil spill on the Ohio River.
read more >


Oil Spill / Oil in Water Analyzer, hand held, accurate and repeatable results in less than 4 minutes. TD-500 Oil in Water Analyzer is available from stock for immediate delivery from Turner Designs Hydrocarbon Instruments, California, USA. Detect crude oil spills such as that on the Delaware River USA in minutes using the same proven field method used on the world’s offshore oil production platforms. Sensitivity to crude oil down to less than 1 ppm in water.

Turner Designs Hydrocarbon Instruments supplies single sample analyzers and continuous on-line oil in water analyzers to all industries from drinking water to power plants, to heavy industry and oil production facilities worldwide. Contact Turner Designs Hydrocarbon Instruments at sales@oilinwatermonitors.com or 1-559 253-1414.


HOT NEWS!

New Hand Held Oil in Water Meter for Produced Water and Crude Oil in Water

Turner Designs Hydrocarbon Instruments (USA) announces the next generation rugged and reliable oil field oil in water monitors for crude oil and produced water applications. The industry leader who brought you the TD-360 FastHEX and the TD-4100 XD continuous on-line oil in water monitors has just released the TD-500 TM hand held / bench top oil in water meter for crude oil. The new UV Fluorescence meter measures oil in Produced Water, Desalter Tail-Water, Crude Storage Tank Water, and in any application where crude oil may be in contact with water. It is viable for all crude oil and most gas production condensates.

It uses the same easy-to-use FastHEX procedure used on the famous TD-360 with the same high accuracy and repeatability but the new TD-500 meter is half the price of the nearest competition. The analysis method is compatible with all popular solvents including hexane, Vertrel, AK-225, Freon, xylene, and others.

The TD-500 is powered by 4 AAA batteries, weighs less than 1 pound and produces oil in water measurements in less than 4 minutes. It requires no special training and measurements correlate to EPA standard oil and grease laboratory methods. It is completely sealed meeting IP 67 Standard. It is water-proof, dust-proof and corrosion-proof and carries the CE mark.

TD500 Fact Sheet