Products TD-3100 Laboratory Fluorometer
TD-3100 Laboratory Fluorometer Print

Download Technical Data Sheet

The TD-3100 is a low cost benchtop instrument that was developed to provide an alternative to industry standard oil and grease methods. Measure samples directly (non-extraction) or with solvent (i.e. hexane) extraction methods.



TD-3100 Features

  • Simple set-up and calibration

  • Low cost per sample analysis

  • Less than 10 seconds per sample

  • Calibrated methods for quantitative analysis

  • Un-calibrated method for relative measurements

  • Results correlate to standard methods

  • Quick-change optics for multiple applications

  • Detection limits range from ppb to ppm depending on application

  • Solid Reference Standards available for quick performance checks

  • Sample compartment accommodates 25 x 150 mm round, 13 x 100 mm round, or 10 x 10 mm square cuvettes

Applications include:

  • Heat Exchanger Leak Detection

  • Produced Water

  • Industrial Wastewater

  • Ground Water

  • Storm Water

  • Bilge Water

  • Soil Extract Analysis

Target Hydrocarbons

  • Crude Oil

  • BTEX

  • Phenol

  • Styrene

  • Gasoline

  • Diesel

  • Jet Fuel

  • Fuel Oils

  • Kerosene

  • Heat Transfer Fluids

  • Transformer Oils

  • Lube Oils

  • Hydraulic Oils

Product Specifications


Detection Limits:

Ranges from ppb to ppm depending on application.

Power:

External power supply, 100-240 VAC, Max. 30 watts.

Dimensions:

23.5 cm W x 28 cm D x 21 cm H, (9.25" W x 11" D x 8.25" H).

Weight:

5.9 Kg (13 lbs).

Operating Temperature:

60 - 95°F; 15 - 36°C.

Display:

16 x 2 character LCD; (3.86" x .86"; 9.8 cm x 2.18 cm).

Keypad:

4 x 5 keys (3" x 2.7"; 7.62 cm x 6.86 cm).

Data Output:

100% ASCII format through a 9-pin RS-232 serial cable at 9600 baud.

Sample Adapters:

Sample chamber with the 25 mm adapter accommodates 25 x 150 mm test tubes. Also includes adapter for 13 x 100 mm test tubes. Optional adapter for 10 x 10 x 45 mm square cuvettes. Optional range extending adapter with variable apertures for 10 x 10 x 45 mm square cuvettes.

Filter Cylinder:

Accommodates eight, 1-inch round filters, (four excitation and four emission).

Software:

Menu-driven microprocessor-controlled.

Detector:

Factory-installed photomultiplier tube. Standard: 300 - 650 nm. Optional Red Sensitive: 185 - 870 nm.

Lamp:

Quartz Halogen Lamp (20 watts; Lamp Life = 2000 hours) or Low Pressure Mercury Vapor Lamp (4 watts; Lamp Life = 8000 hours).

Printer:

Optional EpsonTM printer (27 cm W x 36 cm D x 13 cm H; 10.8" W x 14.4" D x 5.2" H) or Serial Printer (19.75 cm W x 20 cm D x 9.5 cm H; 7.9" W x 8.0" D x 3.8" H).

Material:

UL-approved polyurethane. Sheet metal back and base.

Readout:

Direct Concentration or Raw Fluorescence.

Calibration:

Multi-point Calibration for Direct Concentration Measurement or Single Point Raw Fluorescence Calibration.

Blank:

Reads and subtracts Blank.

Discrete Sample Averaging:

Sample readings can be averaged to improve accuracy (7-second delay; 12-second signal averaging; 5-second display readout).

Warranty:

One-year warranty.

Approvals:

CE, TUV, UL, and C-UL