Products TD-4100 XD
TD-4100 XD Print

Download Technical Data Sheet

The TD-4100 XD is a ruggedized version of the TD-4100 continuous on-line oil in water monitor. The XD is designed specifically for offshore oil production, refining, petro-chemical, mining, and other industries that require robust on-line hardware for severe duty and hazardous area locations. The monitor is skid or wall mounted and constructed of 316 stainless steel.  It also includes an external keypad for operation in corrosive environments. The TD-4100 XD detects and measures crude oil, refined fuels, fuel oils, lubricating or hydraulic fluids and aromatic solvents in water.  Detection limits range from low ppb (µg/L) to high ppm (mg/L).

Why Continuous On-Line Monitoring?
Continuous on-line monitoring provides the most responsive feedback loop for measuring hydrocarbons in water. Continuous monitoring is reliable, effective and recognized for its ability to improve process management for treating, discharging and detecting hydrocarbons in water. Compared to laboratory grab sample analysis, on-line monitoring provides cost effective, continuous, remote, operator unattended measurement of aromatic hydrocarbons in water.

Features of the TD-4100 XD

The Unique Non-Contact Falling Stream Flowcell: There is no contact with any surfaces.  There is no glass tubing or plate to foul.  Hydrocarbons are detected in a stream of water which falls by gravity through an open chamber.  When properly maintained, the falling stream does not contact, dirty or foul the optical windows used for monitoring aromatic hydrocarbons. A proprietary Air Curtain system keeps optical windows fog-free in humid environments or hot water applications.

Hazardous Area Locations: The system is easily configured for hazardous area locations: Class I Division I and Class I Division II, ATEX Zone I and Zone II.

Low Maintenance: There are no internal tubes, pumps or valves to replace. The system's one moving part has a life expectancy of greater than 10 years. Routine maintenance involves changing a lamp twice a year and keeping the sample lines clear.

Direct, Continuous Monitoring: The TD-4100 XD monitors a flowing water stream continuously. No chemicals, no pre-treatment and no manual manipulation of the sample are required to monitor aromatic hydrocarbons.

Accurate: The TD-4100 XD directly measures aromatic hydrocarbons in water with accuracies that consistently correlate to regulated laboratory methods.  The monitor can be calibrated to match laboratory or field oil in water measurement methods with simple inputs to the touch pad.

Sensitive: BTEX, gasoline, diesel, jet fuel, crude oil, aromatic solvents and refined petroleum products containing aromatics are detected by the TD-4100 XD from low ppb (ug/L) to high ppm (mg/L). For example, in clean water, the TD-4100 XD can detect 5 ppb of gasoline or diesel fuel.

Selective: The TD-4100 XD only measures hydrocarbons with minimal interference from solids or turbidity.  It is further selective to the target hydrocarbons depending on the set up and the customer requirements. Fluorescence occurs when a molecule absorbs light energy of one specific wavelength and emits light energy of a longer wavelength. Fluorescent compounds each have a unique signature and these signatures can be displayed as an actual concentration.

Effective Monitoring in Dirty Water: Fluorescence monitoring makes the TD-4100 XD resistant to interferences from turbid or dirty water which impact on-line UV absorption or IR and visible light scatter instruments. Most substances absorb light, but very few fluoresce; if a substance does not fluoresce at specific wavelengths for the monitored aromatic hydrocarbon, it will not interfere.

Operator Friendly: The TD-4100 XD is designed for easy operation. Simple on-board software controls alarms, 4-20 mA output, diagnostics, and calibration.

Options:
Process Chemistry Control for Scale, Iron Sulfide, Wax, etc., Pumps, Internal Heater, Vortex Cooler, Various Communication Protocols, IMO 107(49) certification, Multi-Stream Switching, Special Wetted Materials, ABS, DNV, BV Shipboard Certifications, Project Management Compliance, Data Books, etc., Worldwide Field Service

 

 



Field-Proven Applications

Produced Water

  • Overboard Discharge Compliance and Process Control
  • Re-Injection Or Water Flood Water Quality Control
  • Produced Water Reuse  - RO Feed Water, Steam Generator Feed Water

Non-Contact Cooling Water

  • Heat Exchanger Leak Detection
  • Boiler Feed Protection
  • Cooling Tower Protection
  • Open-Loop Discharge

Wastewater

  • Process Water Discharge
  • Industrial Discharge

Marine Water

  • Drilling and Production Rig Slop Tanks / Deck Drains
  • Bilge Water Discharge
  • Ballast Water Discharge

Hydrocarbons Detected

  • BTEX
  • Gasoline
  • Diesel
  • Jet Fuel
  • PAH's (Poly-aromatic hydrocarbons)
  • Creosol
  • Crude Oil
  • Heat Transfer Fluids
  • Aromatic Solvents
  • Aromatic Chemicals (Styrene, Phenol, etc.)
  • Lubricating Oils
  • Fuel Oil
  • Longwall Fluid

The Water

  • Oil-Produced Water
  • Deck Drains / Slops Tanks
  • Process Water
  • Non-Contact Cooling Water
  • Ballast Water
  • Bilge Water
  • Industrial Wastewater
  • Hydroelectric Water
  • Storm Water
  • Groundwater
  • Municipal Wastewater
  • Potable Water

 

TD-4100 XD Specifications



Dimensions:

74.0" x 20.0" x 25.0" (187 cm x 51.8 cm x 64 cm)

Weight:

110 lbs (50 kg) without accessories

Power Requirements:

110 - 240 VAC, 50/60 Hz, 2A

Plumbing Requirements:

2.0 - 3.0 gpm (8 - 12 L/min), pressure < 50 psi, 2" (5.01 cm) unrestricted drain

Operating Temperature:

32 - 120° F (0 - 49°C). Contact Turner Designs regarding freeze protection.

Operational Principle:

Fluorescence

Detection Range:

1 µg/L -> 1000 mg/L Depending on the hydrocarbon and the water quality

Stability:

5% or better over 90 days

Response Time:

Continuous real-time response

Sample Temperature:

<205°F (96°C) Sample must be liquid at atmospheric pressure

Calibration:

Multi-point calibration or direct uncalibrated readings

Alarms:

Early Warning and High Alarm; critical components are linked to alarms. Local Alarm: local audible: local audible; LCD alarm message

Outputs:

Signal: 4 - 20 mA, isolated. External Alarm/Device Control: 2 user-settable, independently-fused, solid-state alarm relays (AC relay or optional DC relay); relays user-settable as Normally Open or Normally Closed; user-settable set points and delays

Diagnostics:

Self diagnostics: internal failure mode linked to relays and LCD display

Security:

Password protected for Master and User ID; padlockable cabinet

Electronics Cabinet:

316 stainless steel: NEMA 4X

External Keypad:

316 stainless steel

Maintenance:

Lamp (change twice yearly); routine cleaning of plumbing

Air Purge (optional):

Class I Division I; Class I Division II, ATEX Zone I, Zone II

Data Logger (optional):

Digital data storage via 4 - 20 mA output

Sample Pump:

Optional

De-aerator (optional):

316 stainless steel gravity feed system removes suspended gas and regulates sample flow. Includes Auto Valve for automatic shutoff of flow to the flow cell in a low pressure condition.

 

 

 

Sales & Service Partner login